Your voltage
Every model is available in the voltages offered for its compressor. “D” models are 230 V single-phase.
Heating and cooling capacity, COP and cabinet size for all 52 rated Polar Bear water-source heat pumps, at well-water (50°F) and closed-loop (32°F) entering water temperatures.

Every model is available in the voltages offered for its compressor. “D” models are 230 V single-phase.
ECM fan motors as standard, or three-phase motors with inverters.
Twin desuperheaters, 6,000 or 12,000 Btu/h, for domestic hot water production.
Electric duct heaters from 5 to 20 kW, for emergency back-up only. Units are sized to carry the full heating and cooling load.
Two-step compressor models stage output to the load, which helps on retrofits where the existing ductwork is smaller than ideal.
Vertical, horizontal and split water-to-air, water-to-water, triple-function, pool dehumidification and condo units with built-in HRV.
Reading a model number: PBVE-56DS12K15
PBVEFamily: vertical water-to-air, standardD230 V single-phase powerS12Twin desuperheaters, 12,000 Btu/hK1515 kW electric duct heaterCompact vertical units with scroll compressors, for smaller homes and zones.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PBSC-26DK5 | Part load | 26,000 | 17,000 | 15,000 | 19,000 | 17,000 | 4.3 | 3.6 | 16.9 | 16.1 |
| Full load | 26,000 | 22,000 | 28,000 | 25,000 | 4.4 | 3.7 | 17.1 | 16.2 | ||
| PBSC-24DK5 | Single stage | 24,000 | 24,000 | 20,000 | 26,000 | 23,000 | 4.3 | 3.6 | 16.9 | 16.1 |
| PBSC-20DK5 | Part load | 20,000 | 13,000 | 12,000 | 15,000 | 13,000 | 4.3 | 3.6 | 16.9 | 16.1 |
| Full load | 20,000 | 17,000 | 22,000 | 19,000 | 4.4 | 3.7 | 17.1 | 16.2 | ||
| PBSC-14DK5 | Single stage | 14,000 | 16,000 | 14,000 | 18,000 | 16,000 | 4.3 | 3.6 | 16.9 | 16.1 |
Compact vertical water-to-air units with a 26-inch-square footprint.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PBMC-36S6K10 | Single stage | 36,000 | 36,000 | 30,000 | 38,000 | 34,000 | 4.3 | 3.8 | 17.4 | 16.5 |
| PBMC-35S6K10 | Part load | 35,000 | 23,000 | 19,000 | 24,000 | 22,000 | 4.3 | 3.8 | 17.4 | 16.5 |
| Full load | 35,000 | 29,000 | 37,000 | 33,000 | 4.2 | 3.7 | 17.1 | 16.2 | ||
| PBMC-32S6K10 | Single stage | 31,000 | 32,000 | 27,000 | 34,000 | 30,000 | 4.2 | 3.9 | 17.4 | 16.8 |
| PBMC-30S6K10 | Part load | 30,000 | 21,000 | 17,000 | 22,000 | 19,000 | 4.3 | 3.6 | 16.9 | 16.1 |
| Full load | 31,000 | 26,000 | 33,000 | 29,000 | 4.4 | 3.7 | 17.1 | 16.2 | ||
| PBMC-28S6K10 | Part load | 26,000 | 19,000 | 15,000 | 20,000 | 17,000 | 4.3 | 3.6 | 16.9 | 16.1 |
| Full load | 28,000 | 23,000 | 30,000 | 27,000 | 4.4 | 3.7 | 17.1 | 16.2 | ||
| PBMC-26S6K10 | Single stage | 25,000 | 26,000 | 22,000 | 28,000 | 25,000 | 4.3 | 3.6 | 16.9 | 16.1 |
The standard vertical water-to-air range, single compressor.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PBVE-64DS12K20 | Part load | 60,000 | 42,000 | 38,000 | 47,000 | 43,000 | 4.2 | 3.7 | 17.6 | 16.8 |
| Full load | 64,000 | 56,000 | 70,000 | 64,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBVE-60DS12K20 | Single stage | 57,000 | 60,000 | 50,000 | 66,000 | 60,000 | 4.1 | 3.7 | 17.2 | 16.3 |
| PBVE-56DS12K15 | Part load | 51,000 | 37,000 | 34,000 | 40,000 | 37,000 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 56,000 | 50,000 | 60,000 | 56,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBVE-55DS12K15 | Single stage | 50,000 | 55,000 | 49,000 | 59,000 | 55,000 | 4.3 | 3.8 | 17.6 | 16.7 |
| PBVE-48DS12K15 | Single stage | 42,000 | 48,000 | 40,000 | 49,000 | 46,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| PBVE-46DS12K15 | Part load | 40,000 | 31,000 | 26,000 | 31,000 | 29,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 46,000 | 38,000 | 47,000 | 44,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBVE-40DS12K10 | Part load | 35,000 | 26,000 | 23,000 | 28,000 | 26,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 40,000 | 34,000 | 42,000 | 38,000 | 4.3 | 3.8 | 17.4 | 16.5 | ||
| PBVE-34S12K10 | Part load | 30,000 | 24,000 | 20,000 | 24,000 | 23,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 34,000 | 30,000 | 36,000 | 34,000 | 4.3 | 3.8 | 17.4 | 16.5 |
The largest single-compressor vertical units.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PBSM-96DS12K20 | Single stage | 83,000 | 96,000 | 82,000 | 98,000 | 92,000 | 4.0 | 3.6 | 16.8 | 16.1 |
| PBSM-78DS12K20 | Single stage | 70,000 | 78,000 | 68,000 | 84,000 | 78,000 | 4.2 | 3.8 | 17.1 | 16.4 |
| PBSM-68DS12K20 | Part load | 60,000 | 46,000 | 40,000 | 50,000 | 46,000 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 68,000 | 60,000 | 74,000 | 68,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBSM-64DS12K20 | Single stage | 57,000 | 64,000 | 56,000 | 70,000 | 64,000 | 4.3 | 3.8 | 17.6 | 16.7 |
Vertical water-to-air units with triple function.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PBST-96DS12K20 | Single stage | 83,000 | 96,000 | 82,000 | 98,000 | 92,000 | 4.0 | 3.6 | 16.8 | 16.1 |
| PBST-78DS12K20 | Single stage | 70,000 | 78,000 | 68,000 | 84,000 | 78,000 | 4.2 | 3.8 | 17.1 | 16.4 |
| PBST-68DS12K20 | Part load | 60,000 | 46,000 | 40,000 | 50,000 | 46,000 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 68,000 | 60,000 | 74,000 | 68,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBST-64DS12K20 | Single stage | 57,000 | 64,000 | 56,000 | 70,000 | 64,000 | 4.3 | 3.8 | 17.6 | 16.7 |
| PBST-56DS12K15 | Part load | 51,000 | 37,000 | 34,000 | 40,000 | 37,000 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 56,000 | 50,000 | 60,000 | 56,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBST-55DS12K15 | Single stage | 50,000 | 55,000 | 49,000 | 59,000 | 55,000 | 4.3 | 3.8 | 17.6 | 16.7 |
| PBST-48DS12K15 | Single stage | 42,000 | 48,000 | 40,000 | 49,000 | 46,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| PBST-46DS12K15 | Part load | 40,000 | 31,000 | 26,000 | 31,000 | 29,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 46,000 | 38,000 | 47,000 | 44,000 | 4.3 | 3.8 | 17.6 | 16.7 |
Horizontal split water-to-air, standard sizes: compressor section and separate air handler.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PHHS-64DS12K20 | Part load | 60,000 | 42,000 | 38,000 | 47,000 | 43,000 | 4.2 | 3.7 | 17.6 | 16.8 |
| Full load | 64,000 | 56,000 | 70,000 | 64,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PHHS-60DS12K20 | Single stage | 57,000 | 60,000 | 50,000 | 66,000 | 60,000 | 4.1 | 3.7 | 17.2 | 16.3 |
| PHHS-56DS12K15 | Part load | 51,000 | 37,000 | 34,000 | 40,000 | 37,000 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 56,000 | 50,000 | 60,000 | 56,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PHHS-55DS12K15 | Single stage | 50,000 | 55,000 | 49,000 | 59,000 | 55,000 | 4.3 | 3.8 | 17.6 | 16.7 |
| PHHS-48DS12K15 | Single stage | 42,000 | 48,000 | 40,000 | 49,000 | 46,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| PHHS-46DS12K15 | Part load | 40,000 | 31,000 | 26,000 | 31,000 | 29,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 46,000 | 38,000 | 47,000 | 44,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PHHS-40DS12K10 | Part load | 35,000 | 26,000 | 23,000 | 28,000 | 26,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 40,000 | 34,000 | 42,000 | 38,000 | 4.3 | 3.8 | 17.4 | 16.5 | ||
| PHHS-34S12K10 | Part load | 30,000 | 24,000 | 20,000 | 24,000 | 23,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 34,000 | 30,000 | 36,000 | 34,000 | 4.3 | 3.8 | 17.4 | 16.5 |
Horizontal split water-to-air, large sizes.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PBHS-96DS12K20 | Single stage | 83,000 | 96,000 | 82,000 | 98,000 | 92,000 | 4.0 | 3.6 | 16.8 | 16.1 |
| PBHS-78DS12K20 | Single stage | 70,000 | 78,000 | 68,000 | 84,000 | 78,000 | 4.2 | 3.8 | 17.1 | 16.4 |
| PBHS-68DS12K20 | Part load | 60,000 | 46,000 | 40,000 | 50,000 | 46,000 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 68,000 | 60,000 | 74,000 | 68,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBHS-64DS12K20 | Single stage | 57,000 | 64,000 | 56,000 | 70,000 | 64,000 | 4.3 | 3.8 | 17.6 | 16.7 |
Water-to-water units for hydronic distribution such as radiant floors.
| Model | Stage | CompressorBtu/h | Heating50°F EWT | Heating32°F EWT | Cooling50°F EWT | Cooling70°F EWT | COP50°F | COP32°F | SEER50°F | SEER70°F |
|---|---|---|---|---|---|---|---|---|---|---|
| PBWW-83DS12 | Single stage | 83,000 | 83,000 | 74,000 | 80,000 | 72,000 | 4.0 | 3.6 | 16.8 | 16.1 |
| PBWW-70DS12 | Single stage | 70,000 | 70,000 | 62,000 | 68,000 | 62,000 | 4.2 | 3.8 | 17.1 | 16.4 |
| PBWW-60DS12 | Part load | 60,000 | 39,600 | 35,000 | 37,000 | 34,000 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 60,000 | 53,000 | 57,000 | 51,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBWW-57DS12 | Single stage | 57,000 | 57,000 | 50,000 | 55,000 | 49,500 | 4.3 | 3.8 | 17.6 | 16.7 |
| PBWW-51DS12 | Part load | 51,000 | 34,000 | 30,000 | 32,000 | 28,500 | 4.4 | 3.9 | 17.9 | 17.1 |
| Full load | 51,000 | 44,800 | 48,000 | 43,200 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBWW-50DS12 | Single stage | 50,000 | 50,000 | 44,000 | 48,000 | 44,000 | 4.3 | 3.8 | 17.6 | 16.7 |
| PBWW-42DS12 | Single stage | 42,000 | 42,000 | 36,500 | 40,000 | 36,000 | 4.4 | 3.9 | 17.6 | 16.7 |
| PBWW-40DS12 | Part load | 40,000 | 26,400 | 23,200 | 26,000 | 22,400 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 40,000 | 35,200 | 38,000 | 34,000 | 4.3 | 3.8 | 17.6 | 16.7 | ||
| PBWW-30S12K10 | Part load | 30,000 | 19,800 | 17,400 | 18,500 | 16,500 | 4.4 | 3.9 | 17.6 | 16.7 |
| Full load | 30,000 | 26,400 | 28,000 | 25,000 | 4.3 | 3.8 | 17.4 | 16.5 | ||
| PBWW-20DK5 | Part load | 20,000 | 13,200 | 11,600 | 11,800 | 10,500 | 4.6 | 3.9 | 17.4 | 16.8 |
| Full load | 20,000 | 17,600 | 18,000 | 16,000 | 4.4 | 3.7 | 17.1 | 16.2 |
Ratings for these families are available on request.
Cabinet 22 × 26 × 72 in. Full ratings on request.
Request ratings ↗Cabinet 72 × 32 × 28 in. Heating 34,000–96,000 Btu/h at 50°F EWT. Full ratings on request.
Request ratings ↗Cabinet 66 × 28 × 26 in. Heating 13,000–34,000 Btu/h at 50°F EWT. Full ratings on request.
Request ratings ↗Cabinet 48 × 42 × 31.5 in. Heating 46,000–96,000 Btu/h at 50°F EWT. Full ratings on request.
Request ratings ↗Full ratings on request.
Request ratings ↗Heating 40,000–83,000 Btu/h at 50°F EWT. Full ratings on request.
Request ratings ↗Cabinet 36 × 36 × 65 in. Full ratings on request.
Request ratings ↗Cabinet 36 × 36 × 64 in. Heating 48,000–96,000 Btu/h at 50°F EWT. Full ratings on request.
Request ratings ↗Ratings as published in the Polar Bear product specification, in Btu/h at the entering water temperature (EWT) shown; cooling efficiency is listed as published (SEER). Selection at your design conditions is confirmed with the factory.
11 editable cabinet assemblies and 88 source-dimensioned views.
Model tables, entering water conditions, efficiency values and cabinet descriptions.
Open specification ↗Serviceability, cabinet construction and system sizing in Dennis Campbell's earlier document. Its model tables differ from the latest 16-page specification above; use that specification for product data.
Read source text ↗13 individual manufacturer photographs. Exact model numbers are withheld where the image does not establish them.