TECHNICAL LIBRARY

Go straight to the source.

The original Dennis Campbell specification is available here with our extraction and source notes.

PDFPRIMARY SOURCE · 16 PAGES

Manufactured heat pump models

Model tables, entering water conditions, efficiency values and cabinet descriptions.

Open specification ↗
DOCHISTORICAL DESIGN PHILOSOPHY

Design principles

Serviceability, cabinet construction and system sizing in Dennis Campbell's earlier document. Its model tables differ from the latest 16-page specification above; use that specification for product data.

Read source text ↗

Download original Word file ↗

PHOTO LIBRARY

Original equipment, every angle.

13 individual manufacturer photographs. Exact model numbers are withheld where the image does not establish them.

Standard vertical water-to-air cabinet; exact model unconfirmed
Standard vertical water-to-air cabinetOriginal manufacturer photo · exact model unconfirmed
Installed branded standard vertical cabinet; exact model unconfirmed
Installed branded standard vertical cabinetOriginal manufacturer photo · exact model unconfirmed
Branded vertical cabinet detail; exact model unconfirmed
Branded vertical cabinet detailOriginal manufacturer photo · exact model unconfirmed
Open standard vertical cabinet; exact model unconfirmed
Open standard vertical cabinetOriginal manufacturer photo · exact model unconfirmed
Three original manufacturer units in shop; exact model unconfirmed
Three original manufacturer units in shopOriginal manufacturer photo · exact model unconfirmed
Open cabinet with air coil; exact model unconfirmed
Open cabinet with air coilOriginal manufacturer photo · exact model unconfirmed
Manufacturer cabinets in production; exact model unconfirmed
Manufacturer cabinets in productionOriginal manufacturer photo · exact model unconfirmed
Service-side cabinet interior; exact model unconfirmed
Service-side cabinet interiorOriginal manufacturer photo · exact model unconfirmed
Installed water-to-water unit; exact model unconfirmed
Installed water-to-water unitOriginal manufacturer photo · exact model unconfirmed
Two installed water-to-water units; exact model unconfirmed
Two installed water-to-water unitsOriginal manufacturer photo · exact model unconfirmed
Ceiling-hung air handler in a mixed mechanical installation; heat pump model unconfirmed; exact model unconfirmed
Ceiling-hung air handler in a mixed mechanical installation; heat pump model unconfirmedOriginal manufacturer photo · exact model unconfirmed
Horizontal split compressor cabinet under assembly; exact model unconfirmed
Horizontal split compressor cabinet under assemblyOriginal manufacturer photo · exact model unconfirmed
Horizontal split air handler under assembly; exact model unconfirmed
Horizontal split air handler under assemblyOriginal manufacturer photo · exact model unconfirmed

Equipment-family package

One source-linked register of all documented and open model rows, cabinet alternatives and image gaps. Source values are not independently certified performance.

Download model matrix (CSV) · Structured catalog (JSON) · Render manifest and missing references

SOURCE NOTES

Open technical questions

45 extracted rows require identifier, cabinet or table clarification before they can appear as verified product pages. The original wording is preserved below.

PBSMSource page 1

The page 1 heading describes a 65-inch cabinet, while its dimensional line states H64 inches. Product pages show the explicit 28 × 36 × 64 inch dimensions and flag the source discrepancy here.

PBMCSource page 3

The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values.

PBRCSource page 5

Heading says PBRC; cabinet heading says PBCD-72; rows are labelled PBSC and cannot be safely normalized.

PBHO/PHHOSource page 8

Section title says PHHO while first four rows use PBHO.

PBHCSource page 9

PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier.

PBHTSource page 11

Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.

PBWW-WWASource page 13

Source reuses PBWW identifiers and lists four possible cabinet styles without mapping any model to a cabinet.

PWWTSource page 14

Four cabinet styles are mentioned but no model-to-cabinet mapping is provided.

PBDHSource page 15

PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.

PASDSource page 16

Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.

All 45 unresolved source rows
Printed identifierSource familyUnresolved questionEvidence
PBHO-96DS12K20PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PBHO-78DS12K20PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PBHO-68DS12K20PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PBHO-64DS12K20PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PHHO-56DS12K15PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PHHO-55DS12K15PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PHHO-48DS12K15PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PHHO-46DS12K15PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PHHO-40DS12K10PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PHHO-34S12K10PBHO/PHHOSection title says PHHO while first four rows use PBHO.[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]
PBHC-34S12K10PBHCPBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier.[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]
PBHC-26DK5PBHCPBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier.[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]
PBHC-24DK5PBHCPBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier.[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]
PBHC-20DK5PBHCPBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier.[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]
PBHC-14DK5PBHCPBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier.[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]
PBHT-96DS12K20PBHTCabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]
PBHT-78DS12K20PBHTCabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]
PBHT-68DS12K20PBHTCabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]
PBHT-56DS12K15PBHTCabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]
PBHT-55DS12K15PBHTCabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]
PBHT-48DS12K15PBHTCabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]
PBHT-46DS12K15PBHTCabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]
PWWT-83DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PWWT-70DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PWWT-60DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PWWT-57DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PWWT-51DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PWWT-50DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PWWT-42DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PWWT-40DS12PWWTFour cabinet styles are mentioned but no model-to-cabinet mapping is provided.[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]
PBDH-83DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBDH-70DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBDH-60DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBDH-57DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBDH-51DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBDH-50DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBDH-42DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBDH-40DS12PBDHPBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]
PBSM-96DS12K20PASDSection is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]
PBSM-78DS12K20PASDSection is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]
PBSM-68DS12K20PASDSection is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]
PBSM-64DS12K20PASDSection is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]
PBVE-56DS12K15PASDSection is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]
PBVE-55DS12K15PASDSection is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]
PBVE-48DS12K15PASDSection is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]

The photographs are original manufacturer equipment images. Exact model plates are not readable, so photos represent equipment types rather than specific catalog model numbers. Detailed image provenance is retained in the private project files.