Vertical water-to-air

Air coil and condensate pan stay in the sealed thermal core. The upper blower section meets it at a dry air joint.
Design objective: deliver the heat pump to the home in two transport sections intended to be easier to bring through a home's doorways and stairways than one cabinet, then join them on site without opening the refrigerant circuit. No envelope or clearance has been defined yet, so fit through any particular opening is not demonstrated. The thermal core carries the whole refrigerant circuit, including the air coil, so nothing refrigerant-carrying crosses the joint. The second section carries the blower and the controls. Configure it, separate it, walk through site assembly and download the summary.
A proposed next-generation architecture. It is not an available, listed, rated or tested product, and no prototype exists. Legacy confirmed models remain the only products documented in the catalog. Loads, carry weights, envelope, materials, connection sizes and performance are unverified until physical prototypes and engineering checks exist.
Native CAD views of two proposed layouts. Geometry is illustrative and awaits engineering validation; these are not photographs of built equipment. Horizontal, triple-function and optional configurations are explored in the diagrams below.

Air coil and condensate pan stay in the sealed thermal core. The upper blower section meets it at a dry air joint.

Both heat exchangers stay in the thermal core. A separately supported service cabinet meets it at four isolated water unions.
All eight views have separate editable CAD and 3D files. Dimensions in those files are visualization geometry, not approved manufacturing dimensions.
Download the complete design study ↓Choices follow physical compatibility rules. Views show the assembled unit, the two sections separated for transport, service removal paths and the exploded modules. The result is a design-review summary, not a quotation.
Site assembly demonstration ·
Two transport sections are what the installer carries into the home. They are distinct from the internal subassemblies (blower tray, filter rack, control panel, condensate pan) that a technician removes for service after the unit is installed.
The heavier section. It holds the whole refrigerant circuit, so carry weight is set by the compressor and exchangers. No weight target is stated; it is an engineering deliverable and will not be an equal split with section 2.
The lighter section. It contains no refrigerant. On vertical builds its frame bears on the core's top rails through alignment pins; on horizontal builds it stands on its own frame beside the core.
| ID | Joint | Applies to | Crosses | Does not cross | Concept construction | Requires validation |
|---|---|---|---|---|---|---|
| J-AIR | Dry gasketed air joint | w2a-v, w2a-h, w2w2a | Conditioned air only, from the core's coil outlet into the blower section | Refrigerant, condensate, water | Flanged perimeter frame on both sections with a closed-cell gasket. Vertical builds: compressed by section 2's weight plus latches, located by alignment pins on the core top rails. Horizontal builds: the sections stand on their own frames and are drawn together by latches or bolts at the vertical flange | Gasket material, compression, leakage at operating static pressure, latch rating |
| J-ELEC | Protected electrical connector | w2a-v, w2a-h, w2w, w2w2a | Line voltage to the compressor and low-voltage sensor and safety circuits | Nothing else | Keyed, latching connector blocks recessed behind a cover so they cannot be damaged in transport; disconnect is external to the unit | Connector current rating, strain relief, listing |
| J-WET | Wet unions with isolation on both sides, drain and vent | w2w | Source and load water between the core exchangers and the service section fittings | Refrigerant | A union on each of the four water lines with an isolation valve on the core side and on the service side, leaving a short drainable segment between them; low-point drains and high-point air vents on the service section. The core's exchangers stay filled behind their valves; only the trapped segment is drained before separation | Union and valve size, material and pressure rating; drain and vent sizing; procedure for refilling and air removal; freeze protection of the filled core during transport or storage |
| J-LOAD | Structural bearing | w2a-v, w2w2a | Weight of section 2 into the core rails and base | Loads are not carried by the gasket, ducts or connectors | Section 2 frame rails bear on the core's top rails through alignment pins; each section stands on its own frame when separated | Rail stiffness, pin shear, seismic restraint where required |
Water-to-water separation procedure
The heavy core stays at floor level. Return air enters the core through the filter rack, crosses the air coil, then passes the dry air joint into the blower section, which discharges to the supply duct. The filter is upstream of the coil, the condensate pan stays with the coil, and the controls sit above the pan.
Why: No refrigerant line crosses the transport joint; the heavier section is never lifted onto another section; condensate never crosses the joint.
Return air enters the lower blower section and is pushed up through the coil in the core above.
Why: The heavier core would have to be lifted onto the blower section during installation, and the condensate pan would sit above the blower and controls, against the legacy practice of keeping controls above the pan.
The air coil rides in the upper section and the compressor and water exchanger stay below.
Why: A refrigerant line would cross the transport joint, so separation would need a field refrigerant coupling or recovery. That cannot be shown as a dry joint and contradicts the sealed-circuit objective.
Each rule states why it exists.
Common modules are shared by every build; the service equipment and optional sections give each unit its function. No ratings are stated.
The whole refrigerant circuit, factory brazed, charged and sealed inside the thermal core. It includes the application exchanger (air coil, load-water exchanger, or both on the triple-function core), so it is built for one application and is not field-convertible. It has no field refrigerant joints and no refrigerant line crosses the transport joint.
Sealed. Any work on this circuit is refrigerant service requiring recovery, evacuation and recharge by a licensed technician. It is reachable from the core's front and side panels; it is never separated at the transport joint.
The non-refrigerant equipment that gives the unit its application. On air and triple-function builds the blower and supply collar live in section 2 across the dry air joint; the filter rack and condensate pan stay on the core because they belong with the coil. On water-to-water builds the valves, drains, vents, meters and circulator flanges form the hydraulic service section.
Blower tray, filters, condensate pan and hydraulic fittings are removable without refrigerant work. Air-coil work is refrigerant service on the core.
A fixed connection strip on the core carrying every water and condensate penetration through grommets. Pressurized field joints are unions or flanges outside the cabinet, never at the grommet. On water-to-water builds the unions, with isolation valves on both sides, are the wet transport joint to the service section.
External unions allow the core to be isolated and disconnected without cutting pipe. Circulators sit in the external piping, following legacy practice.
A separate compartment with its own door in section 2. On vertical builds it sits above the core's condensate pan and drains, which reduces its exposure to condensate leaks; pan overflow protection and compartment isolation remain design considerations. It is separated from the refrigerant space by the transport joint. Standard relays and a generic anti-short-cycle board follow the legacy philosophy. Power to the compressor crosses the joint through the protected connector.
Own door. Line-voltage disconnect is external to the unit.
Each transport section has its own frame so it stands and travels on its own. The core frame carries isolation mounts and levelling feet. On vertical builds section 2's frame bears on the core's top rails through alignment pins; on horizontal and water-to-water builds section 2 stands on its own supports beside the core. Powder-coated galvanized panels, 1-inch acoustic lining and removable front and side panels follow legacy construction.
Panels are removable without tools on the concept; fastener type is undefined.
Field-attachable sections that contain no refrigerant joints. Each one must satisfy the compatibility rules and adds its own protective devices and electrical coordination.
Each section is removable as a whole after electrical isolation.
What crosses each boundary, whether it is made in the factory or the field, whether it is sealed, and what engineering must still validate.
| ID | Between | Medium | Concept interface | Factory or field | Sealed | Requires validation |
|---|---|---|---|---|---|---|
| I1 | T2 to T1 (J-AIR) | Conditioned air | Flanged perimeter frames with a closed-cell gasket; alignment pins (vertical) or guide pins and latches (horizontal) | Field, dry | Air gasket | Gasket compression and leakage at operating static, latch rating |
| I2 | T2 to T1 (J-ELEC) | Line and low voltage | Keyed, latching connector blocks recessed behind a cover | Field, plug | n/a | Connector current rating, strain relief, listing |
| I3 | T2 to T1 (J-LOAD, vertical builds) | Structural | Section 2 rails bear on core rails through pins; each section has its own frame | Field | n/a | Rail stiffness, pin shear, seismic restraint |
| I4 | T2-W to T1-W (J-WET) | Source and load water | Unions with isolation valves on the core side and the service side; each of four trapped segments has its own drain and vent on the T2 side of the union. Core nipples pitch toward the service drains; complete drain-down requires validation | Field, wet (trapped segment drained before separation) | Open water circuit | Union and valve size, material, pressure rating; refill and air-removal procedure; freeze protection of the filled core |
| I5 | M1 to M2-A (inside T1) | Refrigerant (air coil) | Air coil is part of the sealed core; the condensate pan sits under it | Factory brazed | Sealed | Coil access for recovery-based service, condensate carry-over |
| I6 | M1 to M3 | Source water | Type L copper stubs through grommets to external unions | Field joint outside cabinet | Open water circuit | Connection size, material, pressure rating, freeze protection |
| I7 | M1 to M3 | Domestic hot water (option) | Double-wall desuperheater stubs to bronze external fittings | Field joint outside cabinet | Open water circuit | Relief valve, high limit, flow proving, scald protection |
| I8 | Condensate pan to M3 | Condensate | Stainless pan drain through a grommet to an external trap; pan and coil both in T1 | Field | Gravity drain | Pan slope, trap depth, overflow switch on horizontal builds |
| I9 | M4 to M1 (through J-ELEC) | Line and low voltage | Contactor to compressor and pressure switches to control circuit through the joint connector | Field, plug | Bulkhead on the core side | Compartment separation from refrigerant space |
| I10 | M4 to field | Line and low voltage | External disconnect; thermostat and accessory terminal strip | Field | n/a | Disconnect rating, terminal labelling |
| I11 | M6 heater to T2 and M4 | Air and electrical | Supply-side flanged section with proving switch and limits wired to M4 | Field | n/a | Airflow proving, limit redundancy, added static pressure |
| I12 | M6 HRV to T1 return path and T2 supply path | Air | Separate HRV section joined by field ductwork: fresh-air duct into the core's return-air path upstream of the filter rack, stale-air duct from the return or supply path per the balancing design, outdoor and exhaust collars on the HRV | Field ductwork | n/a | Balancing, defrost, condensate handling in the HRV core, duct routing |
| I13 | M6 stacking frame to M5 | Structural | Frame requiring structural rating, carrying a second complete two-section unit | Field | n/a | Load path, seismic restraint, service clearance to the upper unit |
Service removal paths
Every legacy claim the concept leans on, with its source location, and the architectural principles borrowed from the Seresco references.
| ID | Statement | Source |
|---|---|---|
| L1 | Electrical control cabinetry is located above the condensate pan and drains. | Dennis Campbell, design philosophy document, Cabinet section |
| L2 | Cabinets are satin-coat galvanized steel with baked powder coat; all water pipe openings have rubber grommets; cabinets carry 1-inch acoustic lining. | Dennis Campbell, design philosophy document, Cabinet section |
| L3 | The condensate pan is stainless steel. | Dennis Campbell, design philosophy document, Cabinet section |
| L4 | Standard relays are used instead of proprietary circuit boards; one generic anti-short-cycle and lock-out board is used and can be sourced from any refrigeration wholesaler. | Dennis Campbell, design philosophy document, Electrical Control Components |
| L5 | Closed-loop circulators are installed in the piping just outside the heat pump; hot-water circulators use bronze housings for the domestic circuit. | Dennis Campbell, design philosophy document, Circulator Pumps and Hot Water Circulator sections |
| L6 | The water coil can be ordered in copper for most closed loops or copper-nickel for open loops. | Dennis Campbell, design philosophy document, Water Coil section |
| L7 | A desuperheater is a small water coil that takes heat from the compressor discharge through a double-wall heat exchanger to preheat domestic hot water; S6 and S12 in legacy model names denote twin desuperheaters. | Dennis Campbell, design philosophy document and 16-page specification, page 1 |
| L8 | K5, K10, K15 and K20 in legacy model names denote electric duct heaters of 5, 10, 15 and 20 kW. | Dennis Campbell, 16-page specification, pages 1 to 3 |
| L9 | Legacy families include vertical water-to-air, horizontal split water-to-air with a separate air handler, water-to-water, water-to-water-to-air and a condo unit with a built-in heat recovery ventilator. | Dennis Campbell, 16-page specification, pages 1 to 13 |
| L10 | A flow meter and entering and leaving water thermometers are supplied so system performance can be checked on site. | Dennis Campbell, design philosophy document, Flow Meter and Temperature Thermometers |
| L11 | The reversing valve directs refrigerant to either the air coil or the water coil to switch between heating and cooling; the TX valve regulates refrigerant flow. | Dennis Campbell, design philosophy document, Reversing Valve and TX Valve sections |
Architectural principles only. No Seresco geometry, branding, dimensions, weights, performance data or patented mechanisms are used, and a pool dehumidifier is not a water source heat pump.
Inspiration references and the manufacturer documents the concept is grounded in.