PBVE SERIES · SOURCE PAGE 2

PBVE-46DS12K15

Vertical water-to-air — standard single-compressor

Original Polar Bear water-to-air equipment photograph; exact model unconfirmedOriginal equipment photo · exact model unconfirmed
TECHNICAL DATA

Published source values

Stage numbers and row order follow the source, including its inconsistencies. Spacing is normalized; rows without a printed step number are labelled “Single stage”. Each stage has its own heating, cooling and COP values. Capacity numbers are Btu/h at the stated entering water temperatures (EWT).

Source stageHeat 50°FHeat 32°FCool 50°FCool 70°FCOP 50°F / 32°FSource “SEER” 50°F / 70°F
Step 131,00026,00031,00029,0004.4 / 3.917.6 / 16.7
Step 246,00038,00047,00044,0004.3 / 3.817.6 / 16.7
Compressor nominal40,000 Btu/h
Cabinet W × D × H28 × 34 × 59 in

COP pairs follow the corresponding capacity row in Dennis Campbell's printed table. Cooling efficiency values use the source’s “SEER” label and stated water temperatures; these are not represented as independently certified seasonal ratings. No independent test report was supplied.

Electrical and cabinet notes

230 V single phase indicated by “D” in this family’s source nomenclature; confirm exact configuration with engineering. Cabinet values describe the source family envelope. Confirm clearance, shipping dimensions, voltage and accessories before specifying equipment.